This allowed me to start cad normally without the elevation prompt since i was already running an elevated token, but unfortunately this wouldn't allow me to connect to the network share. Now, with UAC on, i killed the explorer.exe process (via taskmanager) opened up a command prompt by right clicking it and running it as admin and then restarted explorer.exe from there, in the hopes that i would get an explorer process which had inherited the elevated token from the command prompt parent. I've established that the program behaves normally and does connect to network shares when UAC (via turning off admin approval mode) is turned off. UPDATE: I've tried a few things since i posted the above this morning.
I know Autodesk doesn't plan on releasing a patch anytime soon (its nice to have a monopoly in the CAD industry) so i thought i could shim it into working.Ĭan anyone help? Or point me in the right direction. I've gone through the standard user analyzer tool, and have tried implementing the mitigations its suggested, but nothing has worked so far. I think its a UAC issue because as soon as i disable admin approval mode i have access to the shares. This is after i've already confirmed that i can see and open all other files on the network shares from standard windows explorer as well as from other programs. Even though i'm in the admin group on my laptop and after right-clicking and checking run as admin in the compatibility tab. (By being physically in the office and plugging myself in via an ethernet cable) For some reason windows explorer can see our office's network shares (after providing the appropriate credentials) and other programs such as photoshop can open files on these network shares, however when i try to open a file on the network from within AutoCAD i'm told i dont have the right to access the network.
The only problem i have arises when i connect my laptop to my company's network. So i got ArchDesktop 2006 to run fine by clicking compatibility and running as administrator. If you use the Bentley products such as Bently Inroads and want to use it on Windows 64bit then the Longbow Converter is for you.Here's another one for you guys.
The Longbow Converter software works with APS for Architecture too. The Longbow Converter software works with "C & G" Surveying software for AutoCAD.
Run-time error '429': ActiveX component can't create object is a typical error message that the Longbow Converter resolves. The Longbow Converter software works with GlobalCad Toolbox LT running on Windows 7.
If you need to run your AutoCAD plugin AutoNest our Longbow Converter solution works perfectly. The Longbow Converter software works with Flairbase Amine addins for 32bit. The Longbow Converter software works with SurveyMBS perfectly. The Longbow Converter software works with Tyco Sprinkcad too. Error messages the the Longbow Converter resolves are as follows “不支持此操作系统。”, “不支援此作業系統.”,“Produkt AutoCAD tento operační systém nepodporuje.”,“Dieses Betriebssystem wird von AutoCAD nicht unterstützt.”,“Este sistema operativo no es compatible con”,“Ce système d'exploitation n'est pas pris en charge par”,“Ezt az operációs rendszert nem támogatja a(z)”,“Questo sistema operativo non è supportato da”,“このオペレーティング システムは"、”ではサポートされていません。“, “이(가) 지원하지 않는 운영 체제입니다“,“Ten system operacyjny nie jest obsługiwany przez”,“Данная операционная система не поддерживается программой“. if you are having problems with Bentley WaterCAD then our solution offers the fix. Some compatibility flags that are supported are: WINXPSP2, RUNASADMIN, ELEVATECREATEPROCESS, DisableNXShowUI, LARGEADDRESSAWARE, editbin.exe, /3GB. Microvellum Cabinet maker woodworking software is fully supported. All versions of 32bit Cap Studio 20-20 are supported to run on 64bit Windows. This solution fixes all Bentley Road, Bentley Inroad, Site Design, Bentley MX on Windows 64bit issues. If you are working in x86 or 圆4 AutoCAD LT, AutoCAD Map 3D, AutoCAD 2012, AutoCAD Land Desktop, LDT, AutoCAD Architecture, ADT, AutoCAD Civil 3D then the Longbow Converter is for you. The Longbow Converter fixes Slow VBA, makes your Visual Studio 32bit Debugging easier with AutoCAD 32bit, it also lets Visual Studio Edit and Continue feature start working again. The Longbow Converter makes 3rd party ObjectARX or.
Convert AutoCAD 32bit, 32 bit installer MSI 64bit 64bit OS Windows 7 Windows Vista, 64bit, 64 bit, out of process, ODBC on 64bit Windows, Jet Driver on 64bit Windows, CheckFor64BitOS, PLATFORM=NO_WOW_64_PROCESS, InstallExecuteSequence.